Possible causes:Attempting to WRITE or REWRITE a record that is larger than the largest, or smaller than the smallest record allowed by the RECORD IS VARYING clause of the associated file.Attempting The rule of thumb I've used for years is 4 bytes + half the key length gives the average compressed key length stored in the index CI. 4 + (12 / LISTCAT will tell you. The Recording Mode is Variable or Fixed or not defined the same as when the file was created. 3. have a peek here

it will not affect any sequence of the RBA. 3. Can anyone help me out what it means.. > //STEP002 EXEC PGM=IDCAMS > //INDD1 DD DSN=JQVEH.TEST.V.D004.VEH.MASTER.VVMOU001.SORT, > // DISP=SHR > //OUTDD1 DD DSN=JQVEH.TEST.V.D004.VEH.MASTER.VVMOU001.BIT, > // DISP=SHR > //SYSPRINT DD SYSOUT=* > Explore The Micro Focus Web Site via Internet Connect for more information about products and services available from Micro Focus. sg1OA30026Your IBM Storage management guys "should" be able to solve this quickly.

Vsam Repro Return Code 28

All material , files, logos, and trademarks within this site are properties of their respective organizations. We specialize in the creation and deployment of business applications using new or existing technologies and services. The number of significant digits in the relative record number is larger than the size of the relative key data item described for that file. This is where XXXXX was able to successfully create a test version of these files.

These tables are provided for individuals that need to better understand the bit structures and differences of the encoding formats. we verifeid with the Storage management team and confirmed that both the pools are having same properties . Status-key-2Decimal Status-key-2Hex Description 9000 00 No further information. 9001 01 Insufficient buffer space. Robert Sample Global moderator Posts: 3154Joined: Sat Dec 19, 2009 8:32 pmLocation: East Dubuque, Illinois Hasthanked: 1 time Beenthanked: 190 times Top Re: Unable to copy a flat file to

AIXKEY=(12,10) .AXS06 - UNABLE TO EXECUTE VSAM WRITE. Vsam Error Codes Refer to the section for Status-Key-1 being equal to "1" for additional information based on Status-Key-2. 2Invalid Key, an attemprt to access a file failed because the requested key is not Summary This document provides a summary of the two-byte File-Status-Key (sometimes referred to as file return code or file status code). great post to read What can be done to ensure the copy is complete.

SimoTime Technologies makes no warranty or representations about the suitability of the software, documentation or learning material for any purpose. The job was restarted from the top so it will be 10 hours before it gets to the failing step. "So , in the sense , the production job was recovered since my personal job ran fine copying the flat file into VSAM .Note :The flat file doesnt have any duplicates , did ran a sort and verified it .I even checked The last I/O statement executed for the file, before the execution of a DELETE or REWRITE statement, was not a READ statement. 44 A boundary violation exists.

Vsam Error Codes

Whether you want to use the Internet to expand into new market segments or as a delivery vehicle for existing business functions simply give us a call or check the web http://www.ibm.com/support/knowledgecenter/en/SSLTBW_2.1.0/com.ibm.zos.v2r1.ieam600/bb3351.htm Primary File Status The first character of the File-Status-Key is known as status-key-1; the second character is known as status-key-2. Vsam Repro Return Code 28 i have 10 records in a esds file and i want to delete only 1st record ..then what i have to do?.. Idc3351i The ascending key requirements of successive record key values has been violated or the prime record key value has been changed by a COBOL program between successful execution of a READ

Note: If status-key-1 is a nine (9) then status-key-2 is "implementer-defined". navigate here Our customers include small businesses using Internet technologies to corporations using very large mainframe systems. All Rights Reserved. This document may be used to assist as a tutorial for new programmers or as a quick reference for experienced programmers. Iec070i 209-220

I have used the same VSAM file definition to create my personal VSAM dataset and copied the same flat file to it using IDCAMS Repro command .Now , in this situation, StatusKey-1Description by Group 0Successful Completion or non-terminal condition that may be acceptable to continue processing. Taking out the overhead, and with 20% free space per CI, there are 6545 bytes of usable space per CI, which allows 14 records per CI. 14 times 72 gives a Check This Out Back to top kolusuSite AdminJoined: 26 Nov 2002Posts: 11585Topics: 74Location: San Jose Posted: Tue Mar 31, 2009 11:07 am Post subject: suma, The complete description of the error 28 is Code:

You have reached the end of the file. 12 Attempted to open a file that is already open. 13 File not found. Quite often, to reach larger markets or provide a higher level of service to existing customers it requires the newer Internet technologies to work in a complementary manner with existing corporate The first character of the File-Status-Key is known as status-key-1 and defines a group or category.

HesabımAramaHaritalarYouTubePlayHaberlerGmailDriveTakvimGoogle+ÇeviriFotoğraflarDaha fazlasıDokümanlarBloggerKişilerHangoutsGoogle'a ait daha da fazla uygulamaOturum açınGizli alanlarGrupları veya mesajları ara ALLInterview.com Categories | Companies | Placement Papers | Code Snippets | Certifications | Visa

Robert Sample Global moderator Posts: 3154Joined: Sat Dec 19, 2009 8:32 pmLocation: East Dubuque, Illinois Hasthanked: 1 time Beenthanked: 190 times Top Re: Unable to copy a flat file to The combinations of possible values and their meanings are shown below. The error may be caused by an invalid key or the sequence of processing for a valid key. Possible causes:For a READ statement the key value for the current key is equal to the value of that same key in the next record in the current key of reference.For

We have a team of individuals that understand the broad range of technologies being used in today's environments. Kolusu Back to top sumaBeginnerJoined: 23 Jan 2006Posts: 65Topics: 29 Posted: Wed Apr 01, 2009 4:47 am Post subject: Thaks Kolusu, As part of solution I have changed the TRACKS from BLDINDEX INFILE=INFILE,OUTFILE=OUTFILE1, X . this contact form The SimoTime name or Logo may not be used in any advertising or publicity pertaining to the use of the software without the written permission of SimoTime Technologies.

CONDITION CODE IS 12 0 0IDC0002I IDCAMS PROCESSING COMPLETE. And also I increased TRACKS for alternate index from (6000 600) to (7000 700) and also increased CONTROLINTERVALSIZE from 4096 to 8192 for cluster creation. Can you please help? How are all these useful in realtime scenario??Plz helpme out...Its a recent question in IGATE.. 0 Answers iGate, In the COBOL SELECT statement for a KSDS what are the three

We verified that the production VSAM file created is in same test pool . This condition indicates that an attempt has been made to write beyond the externally defined boundaries of a sequential file. 35 An OPEN operation with the I-O, INPUT, or EXTEND phrases Therefore, the file status-key-2 may not always be a numeric value that is easy to display.