Also, check the computer name that is shown as the Source. This peer will be discarded as a time source and NtpClient will attempt to discover a new peer with this DNS name.

Nov 12, 2009 Time Provider NtpClient: No valid response net time /setsntp:pool.ntp.org,0x1 (by default, a windows PC will try to use: time.windows.com,0x1 as its SNTP source) that will ensure that your domain is always accurate, and your client PCs and TechNet Products Products Windows Windows Server System Center Browser   Office Office 365 Exchange Server   SQL Server SharePoint Products Skype for Business See all products » IT Resources Resources Evaluation have a peek here

Storage Software SBS Windows Server 2003 Windows Server 2008 Transferring Active Directory FSMO Roles to a Windows 2012 Domain Controller Video by: Rodney This tutorial will walk an individual through the Any ideas? 0 LVL 83 Overall: Level 83 Windows Server 2003 52 Active Directory 29 MS Server OS 24 Message Active today Expert Comment by:oBdA ID: 242094522009-04-22 If the new If you are experiencing a similar issue, please ask a related question Suggested Solutions Title # Comments Views Activity Windows Server Licensing - Home Server 6 55 2016-12-03 Looking to Virtualize Join the community Back I agree Powerful tools you need, all for free. https://technet.microsoft.com/en-us/library/cc756594(v=ws.10).aspx

Event Id 47 Whea-logger

Article referred and taken from Microsoft Support Center: http://support.microsoft.com/kb/875424 Posted by Dipesh DD at 11/15/2012 04:33:00 pm Email ThisBlogThis!Share to TwitterShare to FacebookShare to Pinterest Labels: Event ID Servers No comments: Ensure that a firewall does not block User Datagram Protocol (UDP) port 123 on the local computer or on the time source peer and that there is no firewall between the Are you an IT Pro? The machines event log should show the following successful events; Event ID 37 (The time provider NtpClient is currently receiving valid time data from..).

x 9 EventID.Net If the computer generating this message is configured to synchronize its time with an NTP server, it is possible that the server is not available. Unauthorized reproduction forbidden. AskNetInfo The right place for sharing IT Solutions - Home About Contact US Links Site Map W32Time warning and error resolved Posted byZafar Email This Post Print This Time Problem Events - On the PDC Emulator Event ID 12 (W32 Time Time Provider NtpClient: This machine is configured to use {text omitted}, but it is the PDC emulator...). W32tm 0x8 The response may have been tampered with and will be ignored.

Like to handle difficult situation and willing to do things where others quit.For friends and family anything. NTP: +0.0000000s offset from server-pdc.yourdomain.co.uk RefID: scarp.mc.man.ac.uk [130.88.203.64] (In the case above the time on server-dc is way out, address that first - it was a Windows 2000 server and running Right click the domain > Operations Masters > PDC Tab. 4. The command displays the status of the Windows Time service synchronization.

Event Source: W32Time Event Type: Error Event ID: 29 Description : The time provider NtpClient is configured to acquire time from one or more time sources, however none of the sources The Computer Did Not Resync Because No Time Data Was Available NtpClient has no source of accurate time. To resolve this problem, configure Windows Time to use client mode with 0x08 (send request as Client mode) when it synchronizes with the time server. Windows Operating System has a built in "Windows Time" service.

Time Provider Ntpclient No Valid Response Has Been Received From Domain Controller

Join the community of 500,000 technology professionals and ask your questions. click for more info Time Problem Events - On Domain Members Event ID 50 (The time service detected a time difference of greater than 5000 milliseconds for 900 seconds...). Event Id 47 Whea-logger Login By creating an account, you're agreeing to our Terms of Use, Privacy Policy and to receive emails from Spiceworks. © Copyright 2006-2017 Spiceworks Inc. Event Id 29 W32time Server 2003 After you type each command, press Enter: w32tm /config /manualpeerlist:NTP_server_IP_Address, 0x8 syncfromflags:MANUAL net stop w32time net start w32time w32tm /resync See ME875424 for details.

Ensure UDP Port 123 is open outbound from the PDC Emulator. navigate here I want all of my DCs to synchronize their time with a headquarters server, so question: How can I manually configure my new DC to synchronize with a server of my Did the page load quickly? This article applies to Windows Server 2003. Time Provider Ntpclient No Valid Response Has Been Received From Manually Configured Peer

NtpClient has no source of accurate time. In addition to the troubleshooting suggestions “Meinolf Weber” provided, I also would like to suggest you check apply the following hotfix: Name resolution may fail on a Windows Server 2003 NtpClient has no source of accurate time. Check This Out TheEventId.Net for Splunk Add-onassumes thatSplunkis collecting information from Windows servers and workstation via the Splunk Universal Forwarder.

By default, Windows Server 2003 domain controllers are configured as time servers and use symmetric active mode to send synchronization requests. NtpClient has no source of accurate time. This command displays the status of the Windows Time service synchornization.

Click Start, click Run, type cmd, and then press ENTER. 2.

Get a "good" server from the list of Internet-based NTP servers see the US Navy Naval Observatory link below. At the top of the Start menu, right-click Command Prompt, and then click Run as administrator. Comments: Vlastimil Bandik - Description: No valid response has been received from manually configured peer - In my case, I was not able to synchronize the PDC server, which was an NtpClient has no source of accurate time.

Event Type:Warning Event Source:W32Time Event Category:None Event ID:47 Date:11/16/2010 Time:4:53:56 PM User:N/A Computer:MYPC Description: Time Provider NtpClient: No valid response has been received from manually configured peer 192.168.2.4 (mydc IP address) All rights reserved.Newsletter|Contact Us|Privacy Statement|Terms of Use|Trademarks|Site Feedback home| search| account| evlog| eventreader| it admin tasks| tcp/ip ports| documents | contributors| about us Event ID/Source search Event ID: Event Execute the following command;

w32tm /monitor 3. this contact form Thursday, January 17, 2013 1:48 PM Reply | Quote Microsoft is conducting an online survey to understand your opinion of the Technet Web site.

That would bring up the warning if the problem is still there. 0 LVL 83 Overall: Level 83 Windows Server 2003 52 Active Directory 29 MS Server OS 24 Message Make sure within the following policy; Computer Configuration>Administrative Templates >System>Windows Time service>Time Providers All the entries are set to "Not Configured" (after altering the policy don't forget to run "gpupdate /force" Feedback: Send comments or solutions - Notify me when updated Printer friendly Subscribe Subscribe to EventID.Net now!Already a subscriber? This message will not be logged again until a successful lookup of this manually configured peer occurs.

In case you want to change time server to any public SNTP server, same command can be used as, net time /setsntp:time.windows.com To manually synchronize time on client machine, net time The Windows Time service acquires a time source peer from the domain heirarchy. For a quick fix run w32tm /resync /rediscover on the server. You can also make the server point to an IP address by double clicking on the time clock then select Internet Time tab type over the current settings like time.windows.com http://support.microsoft.com/kb/816042

Add Cancel × Insert code Language Apache AppleScript Awk BASH Batchfile C C++ C# CSS ERB HTML Java JavaScript Lua ObjectiveC PHP Perl Text Powershell Python R Ruby Sass Scala SQL